Page Copyright @2019 Shanghai Aifafa Instrument Technology Co., Ltd.  www.300.cn 《中华人民共和国电信与信息服务业务经营许可证》 沪ICP备05061880号

TESTING EQUIPMENT

TESTING EQUIPMENT

Stress Relaxation

>>Rotorless RheometerMFR100LiteBrief Descriptions:RotorlessRheometerMFR100Liteisanewly-designed,incompliancewithASTMD5289,fortestingthevisco-elasticpropertiesofrubbercompounds. It'sequippedwiththelate
没有此类产品
Description

>> Rotorless Rheometer MFR 100Lite

Brief Descriptions:

Rotorless Rheometer MFR 100Lite is a newly-designed, in compliance with ASTM D5289, for testing the visco-elastic properties of rubber compounds. It's equipped with the latest temperature control system, advanced temperature probe and precise torque transducer as well as strict quality control in manufacture, which ensure MFR100Lite possessing excellent repeatability, reproducibility and sensitivity at the top level worldwide. Together with incorporating friendly graphical interfaces, powerful data processing capacity, and strong network function, it greatly improves users' testing capability, facility and efficiency.

Typical rotorless rheometer test-standard isothermal cure test:

1

S'—Elastic Torque; S"— Viscous Torque; TanDelta(Hysteresis Loss)—S"/S'; 
TC90 —90% Cure Time; TC50— 50% Cure Time; 
ML— Minimum Torque; MH— Maximum Torque; 
TS1— Scorch Time (time for 1 torque unit after ML); TS2— Scorch Time (time for 2 torque units after ML)

Application of typical isothermal cure test:

 

MFR TanDelta @ML corralates to Die Swell:                                                                        MFR TanDelta @MH corralates to Rebond:
2

Repeatability and Reproducibility:

Test condition: EPDM (Lanxess Chemicals), Oscillation Angle: ±0.5°, 177℃, 100cpm (1.67Hz)

Data

S' @ML

S' @MH

TC10

TC50

TC90

S"@ML

S"@MH

Average value

1.40

11.59

1.41

3.07

5.31

0.91

1.02

Standard deviation

0.028

0.093

0.026

0.028

0.047

0.030

0.028

Repeatability difference coefficient

2.00

0.80

1.84

0.91

0.89

3.29

2.75

Standard deviation

0.069

0.13

0.078

0.089

0.173

0.088

0.086

Reproducibility difference coefficient

4.93

1.12

5.53

2.90

3.26

9.67

8.43

 

Technical Data and Specifications:

Standard

In compliance with ASTM D 5289 and GB-T 16584

Oscillating Angle

Standard: ±0.5°or ±0.2°or ±1.0°;  Options: other Oscillation Angles customizable

Oscillation Frequency

100cpm (1.67Hz)

Sample Volume

About 4.5cm3

Temperature

Microprocessor Control
Temperature Range: room temperature ~200℃
Temperature Resolution: 0.01℃
Temperature Control Precision: ±0.1℃
Absolute Accuracy: ±0.2℃  
Temperature Overheat: less than 0.4℃ at set point
Temperature Recovery Speed: less than 45 seconds
Temperature Rising Speed: less than 5 minutes (room temperature -100℃)

Data Measurement

Data type: Compound Torque S*, Elastic torque S', Viscous Torque S", Hysteresis Loss TanDelta, 
any Scorch Time Point tsx, any Cure Time Point TCx, 
Measuring Range: 0-200 dNm, measuring Precision: 0.01dNm

Test Type

Standard Cure Test (in compliance with ASTM D5289)

Calibration

Torque Spring Calibration

Display

7.5" TFT LCD, 640X480, 16 million pixel

Keyboard

64-key Membrane Keyboard

Embedded System

ARM9 Structure, 200MHz CPU, 64M Memory, 512M Onboard Storage, Linux Kernel

Interface

Fast Ethernet *1, USB 2.0*2, RS232*1

Electricity

220VAC±10%, 7A

Air Pressure

0.44MPa (4.5kg/cm2)

Size

Width: 68cm, Height: 128cm, Deep: 73cm

Weight

Gross Weight: 240kg; Net Weight: 190kg

Packing Size

L x W x H: 89cm x 80cm x 157cm

 

 
Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Previous article